• WELCOME TO SARVAP SOLUTIONS PVT. LTD.
  • +0120-4917407, +91-9313543557
  •    
  • sales@sarvap.com

DSE702 Manual & Auto Start Control Module

DSE702 Manual & Auto Start Control Module

The DSE702 is a compact control module with an hours counter display. The module offers a range of features for single-set applications including low oil pressure, high engine temperature and over speed monitoring.
The controller provides the option of manual or auto start control for the user (must specify type at time of ordering).


OVERALL SIZE

84 mm x 72 mm x 34.9 mm (3.3″ x 2.8″ x 1.4″)


MAXIMUM PANEL THICKNESS

8.0 mm (0.3”)


PRODUCT VARIANTS

0702-00 – 702 Auto Start Control Module (Hours Counter, DSE Logo)
0702-10 – 702 Manual Start Control Module (Hours Counter, DSE Logo)

PANEL CUTOUT SIZE

80 mm x 68 mm (3.1 ” x 2.7″)


WEIGHT

0.16kg


Key Features Key Benefits
Front panel key switch. Ensures the generator can only be operated when the key is used.
Tamper-proof hours counter. Provides accurate information for monitoring warranty and maintenance requirements.
Remote start input (auto version only). Provides a simple connection to operate the generator from a remote location.
Auxiliary shutdown input (manual mode only). Provides a simple input for a remote stop switch.
LED status indication. Provides instant generator operating status.
Engine pre-heat. Warms the engine to a safe temperature at start-up to increase engine life.
Engine monitoring & protection. Protects engine from long-term damage.
LED status indication. Provides instant generator operating status.
DC Supply OUTPUTS GENERATOR
CONTINUOUS VOLTAGE RATING
8 V to 35 V Continuous
CRANK
Solid state 1.2 A negative grounding terminal
VOLTAGE RANGE
15 V – 333 V AC (L-N)
CRANKING DROPOUTS
Able to survive 0 V for 50 mS, providing supply was at least 10 V before dropout and supply recovers to 5 V. This is achieved without the need for internal batteries.
FUEL
Solid state 1.2 A negative grounding terminal
FREQUENCY RANGE
3.5 Hz to 75 Hz
PRE-HEAT
Solid state 1.2 A negative grounding terminal
ELECTRO-MAGNETIC COMPATIBILITY ELECTRICAL SAFETY TEMPERATURE
BS EN 61000-6-2
EMC Generic Immunity Standard for the Industrial Environment.
BS EN 60950
Safety of Information Technology Equipment, including Electrical Business Equipment.
BS EN 60068-2-1
Ab/Ae Cold Test -30°C.
BS EN 61000-6-4
EMC Generic Emission Standard for the Industrial Environment.
BS EN 60068-2-2
Bb/Be Dry Heat +70°C.