The DSE4210 is an Auto Start Control Module that has been developed to provide an outstanding range of features within a compact module size.
140 mm x 113 mm x 43 mm (5.5” x 4.4” x 1.5”)
8.0 mm (0.3”)
4210-01 – 4210 Auto Start Control Module
118 mm x 92 mm (4.6″ x 3.6″)
0.22kg
Key Features | Key Benefits |
---|---|
Clear fault indication notification via front LEDs. | Ensures all fault conditions are clearly highlighted to operators. |
Front panel/PC software configuration. | Provides flexibility throughout installation and operation. |
Power save mode. | Ensures the battery maintains enough power at all times. |
3-phase generator sensing. | Provides true generator sensing. |
600 V ph-ph nominal system compatibility. | Provides global flexibility. |
Configurable DC outputs (2). | Provides multiple installation options. |
Configurable digital inputs (7). | Provides multiple installation options. |
Configurable staged loading outputs. | Provides multiple installation options. |
Fuel and start outputs. | Provides multiple installation options. |
Configurable event log (15). | Provides access to historical alarms and operational status. |
Additional Features |
---|
– Alternator speed sensing. | – Engine pre-heat. | – Start on low battery. |
– Engine maintenance alarms (3). | – Engine run time scheduler. | – Configurable remote start input. |
– Engine speed protection. | – Battery voltage monitoring. | – Alternative configuration. |
– Engine hours counter. |
DC Supply | OUTPUTS | GENERATOR |
---|---|---|
CONTINUOUS VOLTAGE RATING 8 V to 35 V Continuous |
OUTPUT A (FUEL) 10 A short term, 5 A continuous, at DC supply voltage |
VOLTAGE RANGE 15 V to 415 V AC (Ph to N) 26 V to 719 V AC (Ph to Ph) |
CRANKING DROPOUTS Able to survive 0 V for 50 mS, providing supply was at least 10 V before dropout and supply recovers to 5 V. This is achieved without the need for internal batteries. LEDs and backlight will not be maintained during cranking. |
OUTPUT B (START) 10 A short term, 5 A continuous, at supply voltage |
FREQUENCY RANGE 3.5 Hz to 75 Hz |
MAXIMUM OPERATING CURRENT 85 mA at 12 V, 80 mA at 24 V |
AUXILIARY OUTPUTs C & D 2 A DC at supply voltage |
|
MAXIMUM STANDBY CURRENT 40 mA at 12 V, 45 mA at 24 V |
||
MAXIMUM SLEEP CURRENT 35 mA at 12 V, 32 mA at 24 V |
||
MAXIMUM DEEP SLEEP CURRENT 10 uA at 12 V, 10 uA at 24 V |
ELECTRO-MAGNETIC COMPATIBILITY | ELECTRICAL SAFETY | TEMPERATURE |
---|---|---|
BS EN 61000-6-2 EMC Generic Immunity Standard for the Industrial Environment. |
BS EN 60950 Safety of Information Technology Equipment, including Electrical Business Equipment. |
BS EN 60068-2-1 Ab/Ae Cold Test -30°C. |
BS EN 61000-6-4 EMC Generic Emission Standard for the Industrial Environment. |
BS EN 60068-2-2 Bb/Be Dry Heat +70°C. |
VIBRATION | HUMIDITY |
---|---|
BS EN 60068-2-6 Ten sweeps in each of three major axes. 5 Hz to 8 Hz @ +/-7.5 mm, 8 Hz to 500 Hz @ 2 gn. |
BS EN 60068-2-30 Db Damp Heat Cyclic 20/55° C @ 95% RH 48 Hours. |
BS EN 60068-2-78 Cab Damp Heat Static 40° C @ 93% RH 48 Hours. |
SHOCK | DEGREES OF PROTECTION PROVIDED BY ENCLOSURES |
---|---|
BS EN 60068-2-27 Three shocks in each of three major axes 15 gn in 11 ms. |
BS EN 60529 IP65 – Front of module when installed into the control panel with the optional sealing gasket. |