The DSE4210 is an Auto Start Control Module that has been developed to provide an outstanding range of features within a compact module size.


OVERALL SIZE

140 mm x 113 mm x 43 mm (5.5” x 4.4” x 1.5”)


MAXIMUM PANEL THICKNESS

8.0 mm (0.3”)


PRODUCT VARIANTS

4210-01 – 4210 Auto Start Control Module

PANEL CUTOUT SIZE

118 mm x 92 mm (4.6″ x 3.6″)


WEIGHT

0.22kg


Key Features Key Benefits
Clear fault indication notification via front LEDs. Ensures all fault conditions are clearly highlighted to operators.
Front panel/PC software configuration. Provides flexibility throughout installation and operation.
Power save mode. Ensures the battery maintains enough power at all times.
3-phase generator sensing. Provides true generator sensing.
600 V ph-ph nominal system compatibility. Provides global flexibility.
Configurable DC outputs (2). Provides multiple installation options.
Configurable digital inputs (7). Provides multiple installation options.
Configurable staged loading outputs. Provides multiple installation options.
Fuel and start outputs. Provides multiple installation options.
Configurable event log (15). Provides access to historical alarms and operational status.

 

Additional Features
– Alternator speed sensing. – Engine pre-heat. – Start on low battery.
– Engine maintenance alarms (3). – Engine run time scheduler. – Configurable remote start input.
– Engine speed protection. – Battery voltage monitoring. – Alternative configuration.
– Engine hours counter.
DC Supply OUTPUTS GENERATOR
CONTINUOUS VOLTAGE RATING
8 V to 35 V Continuous
OUTPUT A (FUEL)
10 A short term, 5 A continuous, at DC supply voltage
VOLTAGE RANGE
15 V to 415 V AC (Ph to N)
26 V to 719 V AC (Ph to Ph)
CRANKING DROPOUTS
Able to survive 0 V for 50 mS, providing supply was at least 10 V before dropout and supply recovers to 5 V. This is achieved without the need for internal batteries. LEDs and backlight will not be maintained during cranking.
OUTPUT B (START)
10 A short term, 5 A continuous,
at supply voltage
FREQUENCY RANGE
3.5 Hz to 75 Hz
MAXIMUM OPERATING CURRENT
85 mA at 12 V, 80 mA at 24 V
AUXILIARY OUTPUTs C & D
2 A DC at supply voltage
MAXIMUM STANDBY CURRENT
40 mA at 12 V, 45 mA at 24 V
MAXIMUM SLEEP CURRENT
35 mA at 12 V, 32 mA at 24 V
MAXIMUM DEEP SLEEP CURRENT
10 uA at 12 V, 10 uA at 24 V
ELECTRO-MAGNETIC COMPATIBILITY ELECTRICAL SAFETY TEMPERATURE
BS EN 61000-6-2
EMC Generic Immunity Standard for the Industrial Environment.
BS EN 60950
Safety of Information Technology Equipment, including Electrical Business Equipment.
BS EN 60068-2-1
Ab/Ae Cold Test -30°C.
BS EN 61000-6-4
EMC Generic Emission Standard for the Industrial Environment.
BS EN 60068-2-2
Bb/Be Dry Heat +70°C.

 

VIBRATION HUMIDITY
BS EN 60068-2-6
Ten sweeps in each of three major axes.
5 Hz to 8 Hz @ +/-7.5 mm, 8 Hz to 500 Hz @ 2 gn.
BS EN 60068-2-30
Db Damp Heat Cyclic 20/55° C @ 95% RH 48 Hours.
BS EN 60068-2-78
Cab Damp Heat Static 40° C @ 93% RH 48 Hours.

 

SHOCK DEGREES OF PROTECTION PROVIDED BY ENCLOSURES
BS EN 60068-2-27
Three shocks in each of three major axes 15 gn in 11 ms.
BS EN 60529
IP65 – Front of module when installed into the control panel with the optional sealing gasket.